PERFORMANCE OF THE HEXAGONAL CALORIMETER AT PEP-4
19836 pages
Published in:
- Nucl.Instrum.Meth. 217 (1983) 259-264
Experiments:
- SLAC-PEP-004
Citations per year
Abstract: (Elsevier)
A Geiger-mode electromagnetic shower calorimeter has been constructed for PEP-4. Six trapezoidal modules cover 75% of 4 π solid angle in a hexagonal array. Each module contains 40 sense wire planes between 0.25 radiation-length thick lead-laminates, and is divided electrically into submodules of 27 and 13 layers. Half-degree wide hodoscopic channels in projective geometry provide excellent spatial resolution. In each gap three stereo views using the sense wires as well as strips on both cathodes at ±60° to the wires provide good shower reconstruction capabilities in multi-track jet events. Calibration and data analysis procedures are outlined. The performance of the calorimeter in the measurement of Bhabha events and the reconstruction of π 0 's in jet events is in excellent agreement with Monte Carlo simulations. The π 0 mass resolution is MeV (rms).- TALK
- CALORIMETER
- SHOWERS: ELECTROMAGNETIC
- ENERGY: MEASUREMENT
- CALIBRATION
- TRACK DATA ANALYSIS
- SHOWER DETECTOR: PERFORMANCE
- SHOWER DETECTOR: SPATIAL RESOLUTION
- SHOWER DETECTOR: ENERGY RESOLUTION