Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

Aug, 2011
16 pages
Published in:
  • Nucl.Instrum.Meth.A 676 (2012) 96-105
e-Print:
Report number:
  • JLAB-PHY-11-1357

Citations per year

201120142017202020230123456
Abstract: (arXiv)
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
Note:
  • 16 pages, 15 figures
  • Compton polarimeter
  • Jefferson Laboratory
  • Electron beam polarimetry
  • Integrating DAQ
  • photon: calorimeter
  • electron: polarized beam
  • data acquisition
  • Jefferson Lab
  • polarization
  • Compton scattering: backscatter