Pulse-shape discrimination with PbWO(4) crystal scintillators

Jun, 2007
12 pages
Published in:
  • Nucl.Instrum.Meth.A 584 (2008) 129-134
e-Print:

Citations per year

20072011201520192023120
Abstract: (arXiv)
The light output, α/β\alpha/\beta ratio, and pulse shape have been investigated at 25-25^\circ C with PbWO4_4 crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast 0.010.06μ0.01-0.06 \mus and middle 0.10.5μ0.1-0.5 \mus components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times 13μ1-3 \mus and 1328μ13-28 \mus with the total intensity up to 50\approx50% have been recognized for several samples doped by Molybdenum. We found some indications of a pulse-shape discrimination between α\alpha particles and γ\gamma quanta with PbWO4_4 (Mo doped) crystal scintillators.
  • 29.40.Mc
  • Scintillation detector
  • PbWO4 crystals
  • Doping
  • Pulse-shape discrimination