The HBOM Method for Unfolding Detector Effects

Nov, 2011
17 pages
Published in:
  • Nucl.Instrum.Meth.A 701 (2013) 17-24
e-Print:

Citations per year

201120142017202020220123456
Abstract: (arXiv)
We present the Hit Backspace Once More (HBOM) method for correcting a measurement for the effect of an imperfect detector. The HBOM method is a model-independent and potentially data-driven technique that repeatedly applies a parameterisation of the detector effect to observed data. The correction is determined by extrapolating the data so-obtained to a detector effect of zero. We demonstrate this technique using the two particle correlation function, which is an observable that can otherwise be difficult to correct for systematic shifts introduced by the detector.
Note:
  • 17 pages, 8 figures
  • Experimental techniques
  • Unfolding
  • Simulation
  • correlation function: two-particle
  • parametrization
  • data analysis method
  • detector