Arm-length stabilisation for interferometric gravitational-wave detectors using frequency-doubled auxiliary lasers

Dec, 2011
9 pages
Published in:
  • Opt.Express 20 (2012) 81-89
e-Print:

Citations per year

20122015201820212024012345
Abstract: (arXiv)
Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing auxiliary lasers at twice the fundamental measurement frequency to pre-stabilise the arm cavities' lengths. Applying this approach, we reduce the apparent length noise of a 1.3 m long, independently suspended Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control of the system from the auxiliary laser to the measurement laser.
  • gravitational radiation detector: interferometer
  • laser
  • cavity
  • mirror
  • stability
  • control system
  • noise: spectrum