Charged-particle veto detector for the KLπ0ννˉK_L \to \pi^0 \nu \bar\nu study in the J-PARC KO^OTO experiment

Dec, 2012

Citations per year

20112012201301
Abstract: (arXiv)
A charged-particle veto detector was constructed to study the rare decay KLπ0ννˉK_{L} \rightarrow \pi^{0} \nu \bar{\nu} in the J-PARC KO^{\mathrm{O}}TO experiment. This detector consists of 3mm-thick plastic scintillator strips and wavelength shifting fibers coupled with MPPCs at the both ends, which makes it possible to obtain large light output over the wide region. After the construction and installation to the KO^{\mathrm{O}}TO experimental area, its performance was studied using charged particles from KLK_{\mathrm{L}} decays. As a preliminary result, we found that the detector had the light yield larger than 10p.e./100keV and the timing resolution better than 3ns for most regions, which satisfied the requirements to achieve the standard model sensitivety(1011\sim10^{-11}) for the KLπ0ννˉK_{L} \rightarrow \pi^{0} \nu \bar{\nu} detection.
Note:
  • 6 pages, 5 figures, Physics in Collision, Slovakia, 2012
  • photon: yield
  • J-PARC Lab
  • scintillation counter: plastics
  • performance
  • K0(L): rare decay
  • time resolution
  • wavelength shifter: fibre
  • semiconductor detector: pixel