A Two-Stage Injection-Locked Magnetron for Accelerators with Superconducting Cavities
May, 2012
3 pages
Published in:
- Conf.Proc.C 1205201 (2012) 2348-2350
Contribution to:
e-Print:
- 1301.6100 [physics.acc-ph]
Report number:
- FERMILAB-CONF-12-644-AD,
- IPAC-2012-WEPPC059
Citations per year
Abstract: (arXiv)
A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20 dB and the lower power magnetron being frequency-locked from an external source locks the higher power magnetron. The injection-locked two-stage CW magnetron can be used as an RF power source for Fermilab's Project-X to feed separately each of the 1.3 GHz SC of the 8 GeV pulsed linac. We expect output/locking power ratio of about 30-40 dB assuming operation in a pulsed mode with pulse duration of ~ 8 ms and repetition rate of 10 Hz. The experimental setup of a two-stage magnetron utilising CW, S-band, 1 kW tubes operating at pulse duration of 1-10 ms, and the obtained results are presented and discussed in this paper.Note:
- 3 pp. Presented at the 3rd International Particle Accelerator Conference (IPAC-2012), New Orleans, Louisiana, 20-25 May 2012
References(6)
Figures(0)