Abstract: (arXiv)
We report on a wide-field optical monitoring method for revealing local delaminations in sandwich-type composite plates at video-rate by holographic vibrometry. Non-contact measurements of low frequency flexural waves is performed with time-averaged heterodyne holography. It enables narrowband imaging of local out-of-plane nanometric vibration amplitudes under sinusoidal excitation, and reveals delamination defects, which cause local resonances of flexural waves. The size of the defect can be estimated from the first resonance frequency of the flexural wave and the mechanical parameters of the observed layer of the composite plate.
  • (LO) beam object beam piezoelectric actuator optical sensor array beam spliĴer acousto-optic modulators ! illumination beam mirror mirror off-axis beams numerical post-processing sandwich-type composite plate
    • RF signal #1
      • RF signal #2 lens x y z carbon
        • -epoxy aluminum honeycomb
          • FIG. 1: Mach-Zehnder optical holographic interferometer
            • The main laser beam is split into two channels. In the object channel, the optical field is backscattered by the object in vibration at the angular frequency ω, which generates two modulation sidebands at low vibration amplitudes. In the reference channel, the optical field is frequency-shifted by two acousto-optic modulators. The sensor array of the camera records the interference pattern of both optical fields beating against each other, in time-averaging conditions. Images are calculated with a standard holographic rendering algorithm involving a numerical Fresnel transform [18]. the first resonance frequencies of the flexural wave
              • An optical Mach-Zehnder interferometer (Fig. 1) was developed to monitor out-of-plane vibrations. Narrowband imaging is achieved with a frequency-tunable time-averaged laser Doppler holographic imaging scheme on a sensor array. This method enables robust and quantitative mapping out-of-plane vibrations of nanometric amplitudes at radiofrequencies. A high temporal coherence green laser (Cobolt Samba-TFB-150, linewidth < 1 MHz, wavelength λ = 532 nm) was used to illuminate the composite plate in wide field over ∼
                • [20]
                  cm × 20 cm with a total optical power of ∼ 30 mW
                  • This plate is excited by a piezoelectric actuator. Narrowband recording of the map of out-of-plane vibration amplitudes was enabled by holographic interferometry in time-averaging conditions by a 20 Hz frame rate
                    • CCD camera. In such experimental conditions, retrieval of nanometric amplitude oscillations is achieved. The detection process involves both spatial and temporal modulation of the interference pattern through off-axis and frequency-shifting holography [19], frequencydivision multiplexing of the optical local oscillator ensures simultaneous measurement of two modulation sidebands at distinct beating frequencies of the recorded interferogram. Robust imaging of out-of-plane vibration amplitudes at a given frequency is achieved by pixel-to-pixel division of two sideband holograms [17, 20]
                      • The composite is a symmetric sandwich, whose core is a 2.5 cm-thick aluminum honeycomb with 3/8" cells
                        • The skin is a 1.1 mm-thick [0 45 90 -45]s stack of woven carbon fiber plies with epoxy resin of density
                          • ρ = 1.7 g/cm3
                            • Its standard mechanical properties [4], reported in for one woven ply are used to calculate the dispersion relation of the first antisymmetric Lamb mode A0 by the semi-analytical finite element (SAFE) method [21, 22]. This dispersion relation is plotted in Fig. 2. The composite was impacted at 1 J on the monitoring side to provoke a local detachment of the skin from the honeycomb, invisible to the naked eye. In order to create steady-state Lamb waves in the carbon/epoxy plate, a piezo-electric transducer was fixed to the plate as shown in the bottom of Fig. 3(a). The piezo disc (2 cm diameter) is supplied with a sinusoidal signal whose angular frequency ω is swept. Monitoring of resonant Lamb waves is performed by holographic vibrometry
                              • Tab. I
                              • C =
                                      • [60]
                                        15 7 0 0 0
                                        • [60]
                                          7 0 0 0
                                          • [14]
                                            0 0 0
                                            • [4]
                                              0 0 sym. 4 0
                                              • 7