Experimental study of electric breakdowns in liquid argon at centimeter scale

Jan 26, 2014
13 pages
Published in:
  • JINST 9 (2014) P04006
  • Published: Apr 8, 2014
e-Print:

Citations per year

201420172020202320240123456
Abstract: (IOP)
In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).
  • time projection chamber: liquid argon
  • dielectric
  • electric field
  • electrode
  • stability