Beam size and position measurement based on logarithm processing algorithm in HLS II
Jul 30, 2015
7 pages
Published in:
- Chin.Phys.C 40 (2016) 4, 047004
- Published: Apr 15, 2016
e-Print:
- 1507.08515 [physics.acc-ph]
View in:
Citations per year
0 Citations
Abstract: (IOP)
A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode channels of multianode photomultiplier tube (MAPMT) R5900U-00-L16, which has typical rise time of 0.6 ns and effective area of 0.8×16 mm for a single anode channel. In the paper, we first elaborate the simulation results of the algorithm with and without channel inconsistency. Then we calibrate the channel inconsistency and verify the algorithm using a general current signal processor Libera Photon in a low-speed scheme. Finally we get turn-by-turn beam size and position and calculate the vertical tune in a high-speed scheme. The experimental results show that measured values fit well with simulation results after channel differences are calibrated, and the fractional part of the tune in vertical direction is 0.3628, which is very close to the nominal value 0.3621.Note:
- 6 pages, 11 figures, 7 equations
- 29.20.db
- 29.85.Ca
- 29.90.+r
- logarithm processing algorithm
- beam size and position
- multianode photomultiplier tube
- channel inconsistency
- beam position
- beam monitoring
- calibration
References(6)