In situ measurement of relative attenuation length of gadolinium-loaded liquid scintillator using source data at RENO experiment

Collaboration
Sep 29, 2016
11 pages
Published in:
  • JINST 18 (2023) 07, P07020
  • Published: Jul 10, 2023
e-Print:
Experiments:

Citations per year

2016201820202022202410
Abstract: (IOP)
We present in situ measurements of the relative attenuation length of the gadolinium-loadedliquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectorsusing radioactive source calibration data.We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectorsby ∼50% in about four years since the commissioning of the detectors.
Note:
  • 11 pages, 5 figures
  • Liquid detectors
  • Neutrino detectors
  • 78.20.Ci
  • 29.40.Mc
  • scintillation counter: liquid
  • attenuation: length
  • RENO
  • gadolinium: admixture
  • measurement methods