Elimination of the effect of internal activity in LaCl3:Ce scintillator

Jun 18, 2020
15 pages
e-Print:

Citations per year

0 Citations
Abstract: (arXiv)
The Lanthanum Halide scintillator detectors have been widely used for nuclear spectroscopy experiments because of their excellent energy and time resolutions. Despite having these advantages, the intrinsic alpha and beta contaminations in these scintillators pose a severe limitation in their usage in rare-event detections. In the present work, pulse shape discrimination (PSD) with a fast digitizer has been shown to be an efficient method to separate the effect of alpha contamination from the spectrum. The shape of the beta spectrum has been generated with the help of Monte Carlo based simulation code, and its contribution has been eliminated from the spectrum. The reduction in the background events generated by both intrinsic beta and alpha activities has been demonstrated. The present study will encourage the application of these detectors in low cross-section measurement experiments relevant to nuclear astrophysics.
Note:
  • 15 pages, 6 figures
  • [1]
    Performance summary: BrilLanCeT M
    • C.M. Rozsa
      ,
    • Peter R. Menge
      ,
    • M.R. Mayhugh
    • [2]
      Scintillation properties of LaBr3:Ce3+ crystals: fast, efficient and high-energy-resolution scintillators
      • E.V.D. van Loef
        ,
      • P. Dorenbos
        ,
      • C.W.E. van Eijk
        ,
      • K.W. Kramer
        ,
      • H.U. Gudel
        • Nucl.Instrum.Meth.A 486 (2002) 254
    • [3]
      Performance of large lanthanum bromide scintillators
      • Peter R. Menge
        ,
      • G. Gautier
        ,
      • A. Iltis
        ,
      • C. Rozsa
        ,
      • V. Solovyev
        • Nucl.Instrum.Meth.A 579 (2007) 6
    • [4]
      Effects of Ce concentration on scintillation properties of LaBr3:Ce
      • J. Glodo
        ,
      • W.W. Moses
        ,
      • W.M. Higgins
        ,
      • E.V.D. van Loef
        ,
      • P. Wong
      et al.
        • IEEE Trans.Nucl.Sci. 52 (2005) 1805
    • [5]

      x 2

      • F. Quarati
        ,
      • A.J.J. Bos
        ,
      • S. Brandenburg
        ,
      • C. Dathy
        ,
      • P. Dorenbos
      et al.
        • Nucl.Instrum.Meth.A 574 (2007) 115
    • [7]
      High energy resolution scintillation spectrometers
      • K.S. Shah
        ,
      • J. Glodo
        ,
      • M. Klugerman
        ,
      • W.M. Higgins
        ,
      • T. Gupta
      et al.
        • IEEE Trans.Nucl.Sci. 51 (2004) 2395
    • [8]
      Temperature dependences of LaBr3(Ce), LaCl3(Ce) and NaI(Tl) scintillators
      • M. Moszynski
        ,
      • A. Nassalski
        ,
      • A. Syntfeld-Kazuch
        ,
      • T. Szczesniak
        ,
      • W. Czarnacki
      et al.
        • Nucl.Instrum.Meth.A 568 (2006) 739
    • [9]
      Scintillation properties of LaCl3:Ce3+ crystals: fast, efficient, and high-energy resolution scintillators
      • E.V.D. van Loef
        ,
      • L.P. Dorenbos
        ,
      • C.W.E. van Eijk
        ,
      • K. Kramer
        ,
      • H.U. Gudel
        • IEEE Trans.Nucl.Sci. 48 (2001) 341
    • [10]
      LaCl3:Ce scintillator for γ-ray detection
      • K.S. Shah
        ,
      • J. Glodo
        ,
      • M. Klugerman
        ,
      • L. Cirignano
        ,
      • W.W. Moses
      et al.
        • Nucl.Instrum.Meth.A 505 (2003) 76
    • [11]
      High-energy-resolution scintillator: Ce3+ activated LaBr3
      • E.V.D. van Loef
        ,
      • P. Dorenbos
        ,
      • C.W.E. van Eijk
        • Appl.Phys.Lett. 79 (2001) 1573
    • [12]
      Stefan Seifert, Ruud Vinke, Herman T van Dam
      • Dennis R. Schaart
        • Phys.Med.Biol. 55 (2010) N179
    • [13]
      The imaging performance of a LaBr3based PET scanner
      • M.E. Daube-Witherspoon
        ,
      • S. Surti
        ,
      • A. Perkins
        ,
      • C.C.M. Kyba
        ,
      • R. Wiener
      et al.
        • Phys.Med.Biol. 55 (2010) 45
    • [15]
      In-beam measurements of sub-nanosecond nuclear lifetimes with a mixed array of HPGe and LaBr3:Ce detectors
      • N. Marginean
        ,
      • D.L. Balabanski
        ,
      • D. Bucurescu
        ,
      • S. Lalkovski
        ,
      • L. Atanasova
      et al.
        • Eur.Phys.J.A 46 (2010) 329
    • [16]
      Response of LaBr3(Ce) scintillators to 2.5 MeV fusion neutrons
      • C. Cazzaniga
        ,
      • M. Nocente
        ,
      • M. Tardocchi
        ,
      • G. Croci
        ,
      • L. Giacomelli
      et al.
        • Rev.Sci.Instrum. 84 (2013) 123505-1
    • [17]
      Juris Meija
      • Tyler B. Coplen
        • Pure Appl.Chem. 88 (2016) 293
    • [18]
      Radiation Detection and Measurement, 2nd Edition, John
      • G.F. Knoll
    • [19]
      Observations on the background spectra off our LaCl3(Ce) scintillation detectors
      • J. Hartwell
        ,
      • R. Gehrke
        • Appl.Radiat.Isot. 63 (2005) 223
    • [20]
      Characterization of alpha contamination in lanthanum trichloride scintillators using coincidence measurements
      • B.D. Milbrath
        ,
      • R.C. Runkle
        ,
      • T.W. Hossbach
        ,
      • W.R. Kaye
        ,
      • E.A. Lepel
      et al.
        • Nucl.Instrum.Meth.A 547 (2005) 504
    • [22]
      Pulse-shape discrimination ofLa halide scintillators
      • C. Hoel
        ,
      • L.G. Sobotka
        ,
      • K.S. Shah
        ,
      • J. Glodo
        • Nucl.Instrum.Meth.A 540 (2005) 205
    • [23]
      Alphagamma discrimination by pulse shape in LaBr3:Ce and LaCl3:Ce
      • F.C.L. Crespi
        ,
      • F. Camera
        ,
      • N. Blasi
        ,
      • A. Bracco
        ,
      • S. Brambilla
      et al.
        • Nucl.Instrum.Meth.A 602 (2009) 520
    • [24]
      Study of 138 La radioactive decays using LaBr3 scintillators
      • F.G.A. Quarati
        ,
      • I.V. Khodyuk
        ,
      • C.W.E. van Eijk
        ,
      • P. Quarati
        ,
      • P. Dorenbos
        • Nucl.Instrum.Meth.A 683 (2012) 46
    • [25]
      Shape of intrinsic alpha pulse height spectra in lanthanide halide scintillators
      • W. Wolszczak
        ,
      • P. Dorenbos
        • Nucl.Instrum.Meth.A 857 (2017) 66