Initial results from the LIGO Newtonian calibrator

Jun 30, 2021
13 pages
Published in:
  • Phys.Rev.D 104 (2021) 8, 082006
  • Published: Oct 15, 2021
e-Print:
DOI:

Citations per year

202120222023202435
Abstract: (APS)
The precise calibration of the strain readout of the LIGO gravitational wave observatories is paramount to the accurate interpretation of gravitational wave events. This calibration is traditionally done by imparting a known force on the test masses of the observatory via radiation pressure. Here, we describe the implementation of an alternative calibration scheme: the Newtonian calibrator. This system uses a rotor consisting of both quadrupole and hexapole mass distributions to apply a time-varying gravitational force on one of the observatory’s test masses. The force produced by this rotor can be predicted to <1% relative uncertainty and is well resolved in the readout of the observatory. This system currently acts as a cross-check of the existing absolute calibration system.