Review of the some specific features of the detecting of heavy recoils
May 22, 2023Citations per year
Abstract: (arXiv)
In this paper, we present the results of the first beam tests of the detection system at the focal plane of the Dubna Gas-Filled Recoil Separator-2 (DGFRS-2), which receives beams from the DC-280 FLNR cyclotron. The high beam intensity of Ca heavy ions from the cyclotron enables us to obtain a number of superheavy recoils sufficient to compare both the measured and calculated spectra of superheavy recoils implanted into a silicon detector. A real-time algorithm to search for an Evaporation Residue (ER) -- correlated sequences is described in brief. It should be noted that the DGFRS-2 spectrometer operates in conjunction with the 48x128 strip DSSD (Double-sided Silicon Strip Detector; 48x226 mm2) detector and a low-pressure pentane-filled gaseous detector (1.2 Torr; 80x230 mm). A block-diagram of the spectrometer and the event format are also presented. Special attention is paid to the response of a low-pressure pentane-filled DeltaE multiwire proportional chamber for recoils of Fl, synthesized in the Pu+Ca Fl +3n complete fusion nuclear reaction. Some actual parameters of the detection system have also been extracted from Yb + Ca, Th + Ca, Am + Ca, U + Ca reactions. The effect of neighbor strip charge sharing for the ohmic side of the DSSD detector is also under consideration.Note: