The upgrade proposal for the Belle II experiment focuses on improving the time resolution for the KLM detector. We investigated the feasibility of incorporating Time-of-Flight system for muon and KL detections within the Belle II KLM framework, which utilizes plastic scintillators and SiPM readouts. To achieve this, we developed high-speed front-end electronics and arrays optimized for SiPM detection. By implementing constant fraction timing and employing a weighted average of dual-end timing, we significantly enhanced the timing accuracy for particle detection. Comprehensive testing and analysis show that a plastic scintillator measuring 135 cm in length is capable of achieving a time resolution of (70±7) ps. Furthermore, a shorter 50 cm plastic scintillator can achieve a time resolution of (47±2) ps.Note: