A fadc-based data acquisition system for the kascade-grande experiment

Collaboration
Sep, 2005
7 pages
Published in:
  • IEEE Trans.Nucl.Sci. 53 (2006) 265-269
e-Print:
Report number:
  • SI-HEP-2005-11

Citations per year

20052006200701
Abstract: (arXiv)
We present the design and first test results of a new FADC-based data acquisition (DAQ) system for the Grande array of the KASCADE-Grande experiment. The original KASCADE experiment at the Forschungszentrum Karlsruhe, Germany, has been extended by 37 detector stations of the former EAS-TOP experiment (Grande array)to provide sensitivity to energies of primary particles from the cosmos of up to 101810^{18} eV. The new FADC-based DAQ system will improve the quality of the data taken by the Grande array by digitizing the scintillator signals with a 250 MHz sampling rate. events per second. Two Grande stations have been equipped with the FADC-based data acquisition system and first data are shown.