Gas pixel detectors for x-ray polarimetry applications

Dec, 2005
16 pages
Published in:
  • Nucl.Instrum.Meth.A 560 (2006) 425-434
e-Print:

Citations per year

200620112016202120250123456
Abstract: (arXiv)
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
  • X-ray polarimetry
  • Micro pattern gas detectors
  • Pixel read-out
  • [1]
    Detection of X-ray polarization of the Crab Nebula 8 (1972)
    • R. Novick
      ,
    • M.C. Weisskopf
      ,
    • R. Berthelsdorf
      ,
    • Linke
      ,
    • R.S. R. Wolff
      • Astrophys.J. 174 L1
  • [2]
    A precisionmeasurement of the X-ray polarization of the Crab Nebula without pulsar contamination L122 (1978)
    • M.C. Weisskopf
      ,
    • E.H. Silver
      ,
    • H.L. Kestenbaum
      ,
    • Long
      ,
    • R. K. S. Novick
      • Astrophys.J. 220 L117
  • [3]
    Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
    • R. Bellazzini
      ,
    • F. Angelini
      ,
    • L. Baldini
      ,
    • F. Bitti
      ,
    • A. Brez
    et al.
      • Nucl.Instrum.Meth.A 535 (2004) 477484
  • [4]
    Gas Pixel Detectors, ICFA Instrumentation Bulletin Spring 2005 Issue, January 12, 2005
    • R. Bellazzini
      ,
    • G. Spandre
  • [5]
    X-Ray Polarimetry with a Micro Pattern Gas Detector with Pixel Read-Out
    • R. Bellazzini
      ,
    • F. Angelini
      ,
    • L. Baldini
      ,
    • A. Brez
      ,
    • E. Costa
    et al.
      • IEEE Trans.Nucl.Sci. 49 (2002) 1216
  • [6]
    • E. Costa
      ,
    • M. Frutti
      ,
    • F. Pica
      ,
    • L. Piro
      ,
    • A. Rubini
    et al.
      • Proc.SPIE Int.Soc.Opt.Eng. 1344 (1990) 23
  • [7]
    The sensitivity of a photoelectric- X-ray polarimeter for Astronomy: The impact of gas mixture and pressure, 405, Polarimetry in Astronomy Silvano Fineschi Ed
    • L. Pacciani
      ,
    • E. Costa
      ,
    • G. Di Persio
      ,
    • M. Feroci
      ,
    • P. Soffitta
    et al.
      • Proc.SPIE Int.Soc.Opt.Eng. 4843 394
  • [8]
    A novel gaseous Xray polarimeter: data analysis and simulation, Polarimetry in Astronomy Silvano Fineschi Ed
    • R. Bellazzini
      ,
    • F. Angelini
      ,
    • L. Baldini
      ,
    • A. Brez
      ,
    • E. Costa
    et al.
      • Proc.SPIE Int.Soc.Opt.Eng. 4843 383
  • [9]
    der Graaf, E.H.M. Heijne, P. Kluit, X., H. van Llopart et al Section A - Detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit, Nuclear Instruments and Methods in Physics Research Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 535, Issues 1-2, 11 (2004)
    • M. Campbell
      ,
    • M. Chefdeville
      ,
    • P. Colas
      ,
    • A.P. Colijn
      ,
    • A. Fornaini
    et al.