Construction and Optimization of Cryogenic Undulators at SOLEIL
Jun, 2018
6 pages
Contribution to:
- Published: Jun, 2018
View in:
Citations per year
Abstract: (JACoW)
With permanent magnets undulator operation at cryogenic temperature, the magnetic field and the coercivity can be enhanced, enabling shorter periods with high magnetic fields. The first full scale (2 m long, 18 mm period) hybrid cryogenic undulator [1] using PrFeB [2] magnets operating at 77 K was installed at SOLEIL in 2011. Photon spectra measurements, in good agreement with the ex-pectations from magnetic measurements, were used for precise alignment and taper optimization. The second and third 18 mm PrFeB cryogenic undulators, modified to a half-pole/magnet/half-pole structure, were optimized without any magnet or pole shimming after assembly but mechanical sortings and some geometrical corrections had been done before assembly. A systematic error on individual magnets on the third U18 was also compensated. In-situ measurement benches, including a Hall probe and a stretched wire to optimize the undulator field at room and cryogenic temperature are presented. An upgrade of these in-situ benches will be detailed with the fabrication of a 15 mm 3 m long PrFeB cryogenic undulator at SOLEIL.- ion
- undulator
- cryogenics
- vacuum
- electron