MINIATURE VACUUM PHOTODIODES FOR CALORIMETERS

1988
2 pages
Published in:
  • Nucl.Instrum.Meth.A 265 (1988) 301-302

Citations per year

1994199519961
Abstract: (Elsevier)
Data are presented on the performance of flat vacuum photodiodes 30 mm in diameter and 8 mm in height and with a quantum efficiency of the photocathode of 24% for NaI(Tl) crystals. The effects of magnetic fields up to 2.3 T have been measured.