The WELL detector
- R. Bellazzini(,)
- INFN, Pisa and
- Pisa U. and
- CERN
- A. Brez(,)
- INFN, Pisa and
- Pisa U. and
- CERN
- G. Gariano(,)
- INFN, Pisa and
- Pisa U. and
- CERN
- L. Latronico(,)
- INFN, Pisa and
- Pisa U. and
- CERN
- N. Lumb()
- INFN, Pisa and
- Pisa U. and
- CERN
13 pages
Published in:
- Nucl.Instrum.Meth.A 423 (1999) 125-134
Report number:
- INFN-PI-AE-98-03
View in:
Citations per year
Abstract: (Elsevier)
We introduce the WELL detector, a new type of position-sensitive gas proportional counter produced using advanced Printed Circuit Board (PCB) technology. The WELL is based on a thin kapton foil, copper-clad on both sides. Charge amplifying micro-wells are etched into the first metal and kapton layers. These end on a micro-strip pattern which is defined on the second metal plane. The array of micro-strips is used for read-out to obtain 1-D positional information. First results from our systematic assessment of this device are reported.- proportional chamber: gas
- proportional chamber: position sensitive
- electrode: microstrip
- plastics
- charge: yield
- efficiency
- neon: organic compounds
- argon