Pulsing a 4.1-MW motor generator system to 34-MW peak power under constant input power operation
Mar, 1999
3 pages
Part of Proceedings, 1999 Particle Accelerator Conference (PAC'99) : New York, New York, March 29-April 2, 1999, 3767-3769
Contribution to:
Citations per year
0 Citations
- talk: New York 1999/03/29
- power supply
- magnet: pulsed
- Brookhaven PS
References(0)
Figures(0)
0 References