Predicted Performance of the LCLS X-Ray Diagnostics
Sep, 200010 pages
Published in:
- AIP Conf.Proc. 581 (2001) 1, 131-140
Contribution to:
- Published: Sep 28, 2001
DOI:
Report number:
- LCLS-TN-00-13
Citations per year
0 Citations
Abstract: (AIP)
An x-ray diagnostics concept is proposed for the Linac Coherent Light Source (LCLS). X-ray diagnostics will provide spectral and spatial measurements of the spontaneous and SASE radiation along the undulator line, and will be complimentary to an electron beam diagnostics. Main goal of the x-ray diagnostics is to measure the radiation gain along the undulator line. Diagnostics setup consists of diamond crystal monochromator and silicon PIN diode and CCD camera detectors. Accuracy and dynamic ranges of x-ray diagnostics are discussed.References(0)
Figures(0)
0 References