Expected performance of a hard X-ray polarimeter (POLAR) by Monte Carlo Simulation

Jul, 2009
15 pages
Published in:
  • Nucl.Instrum.Meth.A 606 (2009) 552
e-Print:

Citations per year

201220142016201820191062
Abstract: (arXiv)
Polarization measurements of the prompt emission in Gamma-ray Bursts (GRBs) can provide diagnostic information for understanding the nature of the central engine. POLAR is a compact polarimeter dedicated to the polarization measurement of GRBs between 50-300 keV and is scheduled to be launched aboard the Chinese Space Laboratory about year 2012. A preliminary Monte Carlo simulation has been accomplished to attain the expected performance of POLAR, while a prototype of POLAR is being constructed at the Institute of High Energy Physics, Chinese Academy of Sciences. The modulation factor, efficiency and effective area, background rates and Minimum Detectable Polarization (MDP) were calculated for different detector configurations and trigger strategies. With the optimized detector configuration and trigger strategy and the constraint of total weight less than 30 kg, the primary science goal to determine whether most GRBs are strongly polarized can be achieved, and about 9 GRBs/yr can be detected with MDP < 10% for the conservative detector configuration