Beam extraction from a synchrotron through a magnetic shield
20093 pages
Part of Proceedings, 17th International Synchrotron Radiation Conference (SR 2008) : Novosibirsk, Russia, June 15-20, 2008, 10-12
Published in:
- Nucl.Instrum.Meth.A 603 (2009) 10-12
Contribution to:
- , 10-12
- SR 2008
Citations per year
0 Citations
Abstract: (Elsevier)
A new beam extraction scheme from a synchrotron is put forward. The main difference from other schemes of extraction is the use of magnetic shields instead of a septum. Magnetic shields are located in the central dipole magnets of a pulsed chicane . The magnetic shield is a multilayer copper-iron tube. Numerical simulations and experimental results for the magnetic shield are presented. A good accordance between them has been shown. The advantages and the area of application of the new extraction s cheme are discussed. The proposed scheme will be used for extraction from a booster synchrotron to a storage ring in a new synchrotron radiation source in Novosibirsk.- Electron beam extraction
- Synchrotron
References(3)
Figures(0)
- [1]
- [2]
- [3]