A Large streamer chamber muon tracking detector in a high flux fixed target application

Collaboration
Feb, 1999
29 pages
Published in:
  • Nucl.Instrum.Meth.A 435 (1999) 354-374
Report number:
  • CERN-EP-99-030,
  • CERN-EP-99-30
Experiments:

Citations per year

20002001200213
Abstract: (Elsevier)
Arrays of limited streamer tubes of the Iarocci type were deployed in our experiment at CERN as part of a forward muon detector system with provisions for the beam to pass through the center of each panel in the array. A total of 16 4 m×4 m panels were assembled with inductive readout strips on both sides of each panel. An active feedback system was deployed to regulate the high voltage to the streamer tubes to insure a constant efficiency for minimum ionizing particles. The arrays were operated in this environment for over five years of data taking. Streamer tube track-reconstruction efficiencies and tube replacement rates are reported.
  • muon: tracks
  • streamer chamber: gas
  • argon: organic compounds
  • avalanche: quenching
  • efficiency
  • electronics: readout
  • data acquisition
  • CERN SPS