Citations per year

0 Citations
Abstract: (JACoW)
HLS storage-ring has been operated for more than twenty-five years. In 2014 we began to upgrade the machine, which is called HLS-II. The emittance is reduced to 40 nmrad, five insertion devices are added and the injection energy increases to 800MeV. Now the machine commissioning has already been completed. The typical life time is 300 mins at 300mA, 800MeV. The average pressure of static and dynamic vacuum are below 2×10⁻⁸ Pa and 1.2×10-7 Pa respectively. The design, installation and commissioning of the vacuum system of the storage ring are detailedly stated in this paper.
  • vacuum
  • storage-ring
  • synchrotron
  • synchrotron-radiation
  • radiation
  • [1]
    Integration of Commercial Sputtering Ion Pumps with Non-Evaporative Getter, VACUUM SCIENCE AND TECHNOLOGY (CHINA), 2004, 24(3): 222-224. Proceedings of IPAC, Richmond, VA, USA WEPMN023 7: Accelerator Technology T14 - Vacuum Technology 2977 Copyright©CC-BY-3.0andbytherespectiveauthors