Results of the Search for Series X-rays From Kaonic Hydrogen
Apr, 1980
12 pages
Published in:
- Z.Phys.A 297 (1980) 11-15
DOI:
Report number:
- CERN-EP-80-45
View in:
Citations per year
Abstract: (Springer)
The X-ray spectrum associated withK− stopping in liquid hydrogen was measured with high resolution Si(Li) detectors. The totalK X-ray yield is not larger than 8×10−4 per stoppedK− assuming no line broadening. A weak line pattern was found, which was tentatively ascribed to theK− HK-series X-rays. The shift and width of the 1s level, deduced from this pattern, are ε1s=+270±80 eV andΓ=560±260 eV, respectively.- HYDROGEN: MESIC ATOM
- K: MESIC ATOM
- ENERGY LEVELS: MESIC ATOM
- ENERGY SPECTRUM: (PHOTON)
- (PHOTON): ENERGY SPECTRUM
- COUNTERS AND DETECTORS: EXPERIMENTAL RESULTS
- EXPERIMENTAL RESULTS: COUNTERS AND DETECTORS
- CERN1 PS
References(7)