A Solenoidal electron spectrometer for a precision measurement of the neutron beta-asymmetry with ultracold neutrons
Jun, 2008
Citations per year
Abstract: (arXiv)
We describe an electron spectrometer designed for a precision measurement of the neutron -asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-Tesla solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-Tesla field-expansion regions. Select results from performance studies of the spectrometer with calibration sources are reported.- 29.40.Cs
- 29.30.Aj
- 29.40.Mc
- 23.20.En
- Neutron beta -decay
- Low-energy electron magnetic spectrometer
- Ultracold neutrons
- n: polarization
- n: semileptonic decay
- asymmetry
References(20)